vGaugeG24N shown
with weather-resist touch screen
vGaugeG24N power and
data connections to remote sensor unit |
Remote Sensor unit |
When connected to vGauge-Remote
sensor unit, up to 16 color digital gauge readings are possible. There is a
16' max cable length with USB and 150' max cable length with RS232
(serial) interface. |
Weather-Proof touch screen |
Completely sealed screen
is water and weather resistant yet allows operation using touch
commands |
Color Display |
8.4" diagonal sunlight
readable color LCD is bright and easy to view. VGA 640X480 pixel
display format can fit up to 24 gauges on a single page. |
Digital Interfaces |
Available with dual
RS232 serial connections to vGauge-Remote sensor unit or PC/Laptop.
|
Multi-function unit |
Can control two remote
sensor units or switch units from a single display for up to 32 gauges
easily accessible via touch commands |
Display Modes |
User defined gauge
displays. Pick from 10 graphic options with customized labels and text
sizes using vDash Virtual Instrument Design software. Load up to 8
different display pages for real-time use. |
Mounting options |
Flush mount in dash or
console. |
Calibration Tables |
12 user modifiable sensor
calibration tables. 256 data lookup points per sensor input. 4
character display lookup for each of 256 data points. |
Supply Voltage |
Operates on 12V-24V DC
supply. Unit draws 1100 mA under normal conditions |
Flash Port: |
Firmware upgrades can be
performed in the field without sending unit to factory via SD memory
card |
Data Format |
RS232 serial digital
protocol contains individual gauge values, display labels, graphic
symbol identifier and gauge screen position in clear text format.
_PCDICGM "000 0180" 12 " 180F" "TEMP" |
Alarms |
Individual min and max
alarms for each of 16 sensor inputs. All alarms are user programmable.
Individual gauge displays will flash or change color when in alarm condition.
Internal audio alarm is also user configurable. |
Capture Interval |
Unit continuously samples
all sensor inputs and performs a multi-point average. Averaged data is
formatted into a NMEA $IIXDR sentence and output once per second.
|
Dimensions |
Rugged aluminum
enclosure measures 9.8" X 7.9" X 1.87" (outside) requires 9"
X 7" cutout |
|
|